Additional Options                  Home      Basket     Search    Contact Us 

                                                                                                                                                                                                                                                      

a
Sign In

Affiliate Login


SMD Resistor Kits
SMD Capacitor Kits
SMD Inductor Kits
SMD Empty Enclosure
Multimeters
Universal Programmer
Oscilloscope Probes
Portable Digital Oscilloscope
Function Generator
Digital Caliper
Digital Clamp Meter
Test leads for DMM/Scope
Cable network tester
Calibrator / Process meter tester
Pico auto scope test leads
Electronic Load
About/Contact us
Soldering Pot
Shipping/Return policy


Process multimeter DC Frequecy Signal source 24V FLUKE
 
Process multimeter DC Frequecy Signal source 24V FLUKE Quantity in Basket: None
Code: H782
Price: $199.99
 
 
Quantity:
 
The H782 Process multimeter compared with FLUKE
Signal Source + digital Multimeter
Brand new with 3 ys warranty
This Calibrator is a IEC 61010, CAT I 30 V and Pollution Degree 2 instrument
delivers 24V DC Voltage  mV Frequency output  
 
 
This meter is a portable and specialized process verification instrument, which presents as a digital verification meter that has both digital multimeter and signal source function, and can measure and output signal simultaneously. Its large liquid crystal digital display can show and measure the output signal value at the same time, and it is equipped with backlight which makes the user easier to read the value. It uses large-capacity rechargeable battery pack and is featured with low voltage indication. Charging and operating for this instrument can be conducted simultaneously (with a charger). Signal output and measurement function of the instrument is mainly designed for on-site verification and service of an instrument in industrial automation field. This instrument is also featured with multimeter function, which makes it an ideal option for field meterman, computer distributed control system maintainer, meter mounter, and can be used as a multimeter by the meterman.
 
1)It delivers 24V DC voltage output (Imax=30mA), which may be used to supply operating source to two-wire system meter.

2)Current output.

3)mV output.

4)Frequency output.

5)Voltage output.

6)The process verification multimeter is used for DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, temperature and break-and-make, diode and triode test.

7)When using, the instrument displays the measured value and its unit symbol

 

The instrument is featured with range auto-switch, reading hold and relative measurement

Technical index

Operating temperature : 23 ± 5℃   Relative humidity: <75%

 

3.2.1 DC voltage
Range
Resolution
Accuracy
400mV
0.1mV
 
 
± (0.1% reading + 3 figures)
4V
1mV
40V
10mV
400V
100mV
1000V
1V
- Input impedance: 10MΩ
- Overload protection: 400mV range: 250V DC or AC (virtual value), 4V-1000V range: 1000V DC or 750V AC (virtual value)
- Max input voltage: 1000V DC

 

Note:
Within the low voltage range, if the test lead is not connected to the circuit under measured, the reading displayed on the instrument may pulse, which should be considered normal for it is caused by the high accuracy of the instrument; if connect the test lead to the circuit under measured, the true measured value will be captured.

 

3.2.2 AC voltage
Range
Resolution
Accuracy
4V
1mV
± (0.8% reading + 3 figures)
40V
10mV
400V
100mV
700V
1V
± (1.0% reading + 10 figures)
- Input impedance: 10MΩ
- Overload protection: 1000V DC or 700V AC (virtual value)
- Max input voltage: 700V AC (virtual value)
- Frequency range: 40 ~ 400Hz
- Display: mean value (virtual value of sine wave)

Note:
Within the low voltage range, if the test lead isn’t connected to the circuit under measured, the reading displayed on the instrument may pulse, which should be considered normal for it is caused by the high accuracy of the instrument; if connect the test lead to the circuit under measured, the true measured value will be captured.

3.2.3 DC current
Range
Resolution
Accuracy
400mA
0.1mA
± (0.1% reading + 5 figures)
4000mA
1mA
40mA
10mA
400mA
100mA
- Overload protection:
mA, mA range: quick fusing cartridge fuse 500mA/250V
- Voltage drop
400mA range: 400mV, 4000mA range: 4V,
40mA range: 400mV, 400mA range: 4V

 

3.2.4 AC current
Range
Resolution
Accuracy
400mA
0.1mA
± (1% reading + 5 figures)
4000mA
1mA
40mA
10mA
400mA
100mA
- Overload protection:
m A, mA range: quick fusing cartridge fuse 500mA/250V
- Voltage drop
400μA range: 400mV, 4000μA range: 4V,
40mA range: 400mV, 400mA range: 4V,
- Frequency range: 40  400Hz
- Display: mean value (virtual value of sine wave)
 
 
400μA range: 400mV, 4000μA range: 4V,
40mA range: 400mV, 400mA range: 4V,
- Frequency range: 40  400Hz
- Display: mean value (virtual value of sine wave)

 

3.2.5 Resistance
Range
Resolution
Accuracy
400Ω
0.1Ω
 
 
± (0.3% reading + 5 figures)
4kΩ
40kΩ
10Ω
400kΩ
100Ω
4MΩ
1kΩ
40MΩ
10kΩ
± (2.0% reading + 5 figures)
- Open-circuit voltage: about 0.25V

- Overload protection: 250V DC or AC (virtual value)

 

3.2.6 Capacitance
Range
Resolution
Accuracy
40nF
10pF
± (2.0% reading + 10 figures)
400nF
0.1nF
4mF
1nF
40mF
10nF
100mF

 

100nF
 

- Overload protection: 250V DC or AC (virtual value)

 

3.2.7 Frequency
Range
Resolution
Accuracy
9.999Hz
0.001Hz
 
 
±10 figures
 
99.99Hz
0.01Hz
999.9Hz
0.1Hz
9.999kHz
1Hz
99.99kHz
10Hz
199.9kHz
100Hz
>200kHz
 
Only for reference
1) Measuring range: 0 ~5MHz
2) Input frequency amplitude: when in 0~100kHz, the amplitude is higher than 500mV。
when in 100kHz~5MHz, the amplitude is higher than 3V.
3)Input frequency amplitude shall not be higher than 10V.

4)Overload protection: 250V DC or AC (virtual value)

 

3.2.8 Circuit break-and-make test
Range Function
If the resistance of circuit under measured lower than 40W, the buzzer in the instrument makes sounds.
- Open-circuit voltage: about 0.5V
- Overload protection: 250V DC or AC (virtual value)

 

3.2.9 Diode test
Range
Resolution
Function
 
1mV
Indicate the approximate value of forward voltage of diode
- The forward DC current is about 1mA
- The backward DC voltage is about 1.5V
- Overload protection: 250V DC or AC (virtual value)
3.2.10 Triode test hFE: 0~4000
- Overload protection: quick fusing cartridge fuse   500mA/250V.
3.2.11 Temperature measurement: K-type thermoelectric couple (optional).
- Overload protection: quick fusing cartridge fuse   500mA/250V.

 

3.2.12 DC voltage signal
Range
Resolution
Accuracy
10V
10mV
± (0.1% reading + 5 figures)
100mV
100μV

 

3.2.13 DC voltage signal
Range
Resolution
Accuracy
22mA          
10μA
±(0.1% reading + 5 figures)
- Load capacity: 0~800Ω (over 1kΩ below 20mA).

 

3.2.14 Frequency signal
Range
Resolution
Accuracy
1~100Hz
0.01Hz
±0.1Hz
100Hz~1kHz
0.1Hz
±0.5 Hz
1~10kHz
1Hz
±5 Hz
- Square wave, duty cycle 50%, amplitude 4V.

 
3.2.15 24V DC voltage output
Voltage
Accuracy
Load capacity
24V           
2%
30mA

 

Accessories:
 
1) A pair of banana plug test leads;

 

2) Carrying bag;

 

 
Shipping:
All orders will ship from our China warehouse by air mail 12-21 business days with track number for free, the track number will e-mail to you. If you need this fast, you can add $20-$35 to ship by express mail, contact us at support@aidetek.com for detail.

 

 

 


Copyright AideTek, 2008-2010. All Rights Reserved